In the air conditioning systems of the Volvo P1800 model series, the refrigerant circulates through rubber hoses between the individual components of the system. These hoses must be pressure-resistant.

v 120817

Sealing cones and screw connections covered with O-rings at the ends. The length and diameter of each hose is adapted to the specific function in the air conditioning system.

If defective refrigerant hoses are replaced

  • Close free hose ends immediately with protective caps
  • Cover the hose connections with new O-rings that have previously been rubbed with compressor oil. Do not use silicone!
  • Tighten screw connections to the specified torque
  • Add lubricant to the refrigerant compressor

For refrigerant R134a

SAE J2064 Type
Working temperature -40 to 125 °C; peak temperature 149 °C
Tube: IIR compound
Reinforcement: 2 textile spirals
Cover: EPDM compound

The size of the hoses is determined by the inner diameter of the hose. The outer diameter varies depending on the manufacturer and is therefore not a measure of the hose specification.

* The information on the length of the refrigerant hoses is only approximate, as the dimensions of the fittings and the routing of the hoses in the engine compartment have not been taken into account!

Hose Size
Inch
Inside Diameter
Inch
Application Length *
DN 6 5/16 Liquid hose: Condenser to Drier
Liquid hose: Drier to Evaporator
ca. 92 cm / 37"
ca. 120 cm / 48"
DN 8 13/32 Discharge hose: Compressor to Condenser ca. 70 cm / 28"
DN 10 1/2 Suction hose: Evaporator to Compressor ca. 132 cm / 52"

 

Hose cutter

Do not cut the hose with a knife or saw blade, as no small parts should get into the hose. A hose cutter, on the other hand, produce a clean and smooth cut surface.

Keywords for search: hose cutter, pipe cutter

rohrschneider

Professional hose cutter up to 42 mm outer diameter. Not suitable for hoses with steel spiral or metal inserts!

hose cutter